          Mitech MHRS-150-P Digital Plastic Rockwell Hardnes

          Brand:

          Mitech

          Model:

          Measuring range:

          HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、HRF:60-

          Resolution Accuracy:

          Communication storage:

          Working time:

          Main unit weight:

          Dimensions:

          550*220*730mm

          Package dimensions:

          62*42*87cm

          Total weight:

          95kg

          Product

          • Overview
          • Graphic
          • Technical
          • Configuration
          • Related

          Product

          • Overview
          • Graphic
          • Technical
          • Configuration
          • Related
          • Product Overview

            Mitech MHRS-150-P Digital Plastic Rockwell Hardness Tester, based on the mechanical principle of hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the depth of the indentation. Capable of inspecting the finished or semi-finished parts of the machined sample, it is suitable for plastic, hard rubber, synthetic resin, friction materials and softer metals. According to statistics, Rockwell hardness testing is the most widely used hardness testing method in metal processing industry, which utilization ratio is more than 70%. With novel appearance, stable performance, intuitive and convenient LCD display, and easy to operate the menu design, it is widely used in the quality control of plastic products, the detection of finished products of resin rubber and other fields like colleges and research institutions. it is the the sophisticated detection equipment to test the plastic and soft metal materials Rockwell hardness.

            Function & application

            l Used for quality control in plastic products;

            l Used for resin rubber finished product testing

            l Demonstration experiment for education and teaching in Colleges and Universities;

            l Hardness testing of materials in scientific research institutions

            Working Principle

            The Rockwell hardness test is taking the diamond cone with 120°apex angle or the hardened steel ball with specified diameter as the indenter to press into sample surface with specific test force, then get the Rockwell hardness of the measured metallic materials according to the sample surface indentation depth.

            The Rockwell hardness measurement principle is shown as below figure. 0-0 is the position that the diamond indenter is not yet in contact with the sample. 1-1 figure is the indenter position under the affect of the preliminary test force, the indentation depth is h1. The preliminary test is to eliminate the influence to the testing result accuracy caused by the roughness of the sample surface. 2-2 in the figure is the indenter position under the influence of the testing force (the preliminary test force and the main test force). The depth is h2. 3-3 in the figure is the indenter position after dismounting the main test force. As the metal elasticity will recovery some degree after deformation, the really indentation depth of the indenter is h3. The plastic deformation caused by the main test force make the indenter pressing into the depth is hh3h1. Rockwell hardness value is determined by the size of h, the greater the depth h, the lower the hardness, otherwise, the higher the hardness.

            In the traditional concept, usually use a constant C minus h to represent the level of hardness, while the depth of indentation per 0.002mm as a unit of hardness. The hardness value obtained is called the Rockwell hardness value, denoted by the symbol HR.

            In the formula, c is a constant (for HRC, HRA, c is 0.2; for HRB, c is 0.26). The Rockwell hardness value HR obtained is an unknown number which is usually read directly on the test machine indicator when testing.

                    It should be noted that the measured hardness values would be different with different indenter and test force. Therefore, the Rockwell hardness testing specifies 15 different hardness test scales according to the different indenter specification and test force sizes. And the HRB, HRC, HRA are the most widely used.  

            Working Conditions

            Operation Temperature1030℃;

            Relative Humidity≤65%;

            The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.

            Instrument Features

            l Widely used for high-precision hardness testing for plastic, hard rubber, synthetic resin, friction material and softer metal;

            l Adopt electronic automatic operation system to control the testing force, easy to operate;

            l Option for various specifications of the indenter, support many types of Rockwell hardness scales testing ;

            l Equipped with high-speed thermal printer, quickly print out the test data;

            l Support the conversion among various hardness scales such as Brinell, Vickers and etc;

            l Adopt large-screen LCD, easy to operate, visually display the test results;

            l Equipped with excellent performance of the carbide indenter, high hardness, wear resistance, good toughness,

             meanwhile with high temperature and corrosion resistance to ensure that the instrument test value is accurate, stable and

             reliable;

            l With the function of threshold overrun automatic alarm, apply to the bulk of finished products or semi-finished pieces of

             paper-by-piece detection;

            l The function of original ambient temperature real-time display can avoid the instrument working in the case of high or low

             temperature for a long time , resulting in increased test error and reducing the service life;

            l Consistent with GB7407、JJG884、ASTMD785、GB/T 3398.2 other relevant standards at home and abroad.

            Operating Method and Attentions

            Instrument Maintenance

            l The test personnel should follow the operating procedures.Before and after the test,it  should be repeated with standard

             block calibration equipment;

            l If the specimen has visible deformation marks on the back and edges, the test result would be useless. It should choose

             the intender or test force to test again;

            l Normally, the first point is only used to offset the gap of each support surface without needing to record the test result.

             Record the statistical test result from the second point;

            l During testing, to ensure accuracy, please make sure the distance between the adjacent indentation center and the

             distance from the indentation center to edge of the specimen is greater than 3mm;

            l Pay attention to palm the instrument for carrying to forbid falling across. Please fix well the measuring lever, counterweight

             and boom before carrying;

            l It is strictly prohibited to turn the variable loading handwheel when the instrument load or unload the test force. Rotating

             the handwheel forcibly will cause the internal gear dislocation, test force in chaos and even damage the internal parts of

             the instrument;

            l Turn off the power after using the instrument;

            l When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And the

             hardness block, indenter should be coated with antirust oil to prevent rusting after using;

            l Long time after the re-enabled,it should be preheated the electrical components before test

            l The hardness tester should be calibrated at least once a year to ensure its accuracy;

            l Don’t disassemble the instrument without authorization, for maintenance related matters, please contact MITECH 

            after-sale service department with 4000600280.

             

          • Preliminary testing force 98.07N,tolerance±2.0%
            Testing force 588.4N,980.7N,1471N,tolerance±1.0%
            Measuring range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、HRF:60-100、HRG:30-94、HRH:80-100、 HRK:40-100、HRL
            Testing force application mode Automatic operation (preliminary test needs manual operation)
            Indenter specification Φ3.175mm steel ball indenter;Φ6.35mm steel ball indenter;Φ12.7mm steel ball indenter
            Display LCD
            Rockwell scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK
            Conversion scale HRA、HRB、HRC、HRD、HR15N、HR30N、HR45N、 HR15T、HR30T、HR45T、HV、HK、HBW
            Duration time 1~30s(The testing force duration time for plastic Rockwell hardness test is 15 seconds)
            Indication error 0.1HR
            Maximum height of specimen 170mm
            Distance of indenter to outer wall 165mm
            Power supply AC220V/50Hz
            Dimensions 550*220*730mm
            Main unit weight 85kg
          ×

          郵箱反饋

          如您在和我公司的交往中遇到問題,可通過以下方式和我們?nèi)〉寐?lián)系!
          您也可以撥打我們客戶服務(wù)熱線:400-0600-280

          *
          *

          MITECH CO. LTD

          TEL :

          86-10-58859527
          008613810243516

          ADD:

          E-506, 1# of ShangDi East Road, Haidian District, Beijing, China

          Email: 

          mvip@mitech-ndt.com

          公眾號
          亚洲国产初高中生女AV,超碰最新公开无码97,亚洲中文字幕无码一,亚洲精品无码专区
            <ul id="xt0w6"></ul>
            <cite id="xt0w6"><listing id="xt0w6"></listing></cite>
              <b id="xt0w6"><meter id="xt0w6"></meter></b>
            1. <thead id="xt0w6"></thead>
                  <form id="xt0w6"><meter id="xt0w6"></meter></form>