          Mitech MHBS-3000 Digital Display Brinell Hardness

          Brand:

          Mitech

          Model:

          Measuring range:

          8~650HBW

          Resolution Accuracy:

          Communication storage:

          Working time:

          Main unit weight:

          130kg

          Dimensions:

          786*565*245mm

          Package dimensions:

          105*78*47cm

          Total weight:

          150kg

          Product

          • Overview
          • Graphic
          • Technical
          • Configuration
          • Related

          Product

          • Overview
          • Graphic
          • Technical
          • Configuration
          • Related
          • Product Overview

            MITECH MHBS-3000 Digital Display Brinell Hardness Tester, based on the mechanical principle of hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the diameter of the indentation.It is novel and high reliable with accurately measurement. With LED display, simple operation, it can visually display the test results to meet the hardness testing requirement for the quality control and qualified assessment of the workpiece sample. It is widely used in metal processing and manufacturing, various metal material’s failure analysis and other fields like colleges and research institutions It’s to improve the work efficiency, product qualification rate, saving production costs necessary professional precision testing equipment.


            Function & application

            l Metal processing industry quality control links

            l Universities teaching and demonstration test

            l The failure test of metal material

            l The material hardness test of scientific research institutions

            Working Principle

            Hardness is not a simple physical quantity, but a reflection of the material elasticity, plasticity, strength and toughness .and hardness test is the most simple mechanical testing method to determine the metal material performance. Also one of the important means to judge the products quality.

            Brinell hardness test: Test force(F) is on the steel ball with certain diameter(D) , pressed on sample surface. After a period of time, cancel the force. The indentation diameter is get by measuring with  micrometer ocular,thus to calculate the average pressure(N/mm2).

             


            Working Conditions

            Working Temperature18℃28℃;

            Relative Humidity≤65%;

            Clean environment, no vibration;

            No corrosive media around.

            Instrument Features

            Suitable for measuring the surface is more rough cast iron, steel and other non-homogeneous specimen Brinell hardness;

            The use of automatic closed-loop pressure sensor control system, can dynamically reflect the loading process load

             changes.

            Modeling novel, strong structure,high reliability and operability , intuitive, high test efficiency;

            Equipped with excellent performance of the carbide indenter, high hardness, wear resistance, good toughness, while high

             temperature, corrosion resistance, to ensure that the instrument measured standard, stable and reliable;

            Support Brinell, Rockwell, Vickers and other hardness standard conversion;

            LCD liquid crystal display screen , menu intelligence tips, easy to operate

            Compliance with ISO 6506, ASTM E10-12, ASTM E-384, GB / T231.2, JIS Z2243 and other relevant domestic and foreign

             standards.

            Operating Method and Attentions

            Instrument Maintenance

            l Each technical requirement of the instrument has already reached the national standards before leaving factory. But its

             disassembly, transportation or voltage after delivery might cause some data in the instrument changed. So to make the

             electronic component in normal operation to reduce the testing error, you can use test force of 29400N(3000kgf) pressing

             times before starting the instrument to eliminate the instrument deformation.

            l The anti-interference component has been installed in the circuit to ensure the transmission of the loading or unloading

             single of the test force at all levels. At the same time, make sure no strong interference source around when using the

             instrument, and power off the instrument after finished the testing.

            l All the screws and the caps have been fasten tightly before the instrument leaving factory. However, the screw and cap

             may become less crowded because that the screw lever for loading and unloading are rotating all the time. If there is

             irregular noise, when the screw lever rotating, please check and tightened the screw and cap as the below figure shown.

             

            Pulley and cap

             

            l The instrument power supply shall be grounded reliably and equipped with voltage-stabilizing device;

            l If there is some slight noise during loading or unloading, it is the loading mechanism making adjustment automatically,

             which is a normal phenomenon.

            l The instrument screw level and other movable surface should be lubricated regular.

            l When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And

             the hardness block, indenter should be coated with antirust oil to prevent rusting after using.

            l Start using again after long time idling, please make testing after preheating the electrical components.

            l The accuracy of the reading microscope has been adjusted before leaving factory. It is prohibited to disassembly without

             authorization. Otherwise, it will reduce the reading accuracy of the micro eyepiece.

            l The storage and using of the reading microscope should avoid dust, damp and corrosive gas environment;

            l If there is dirt on the surface of the reading microscope lens, please wipe it with soft absorbent cotton or lens paper. If

             there is oil pollution, please wipe it slightly by the absorbent cotton with industrial alcohol or ether.

            l Don’t disassemble the instrument without authorization, maintenance related matter, please contact MITECH after-sale

             service department with 4000600280. 

          • The power series 612.5N(62.5kgf)、980N(100kgf)、1225N(125kgf)、1837.5N(187.5kgf)、 2450N(250kgf)、4900N(500kgf)、7350N(750k
            Measuring range 8 – 650 HBW
            Testing Force Application Mode Automatic (loading, holding, unloading)
            Indenter objective lens conversion mode manual operation
            display usage LCD liquid crystal display
            Microocular magnification 20X
            Test force holding time 0~60s
            Minimum division 0.005mm
            Max sample height 225mm
            Max sample width 270mm
            Max distance from head to body 135mm
            Voltage AC 220V/50Hz
            Size 786*565*245mm
            Total Weight 130kg
          ×

          郵箱反饋

          如您在和我公司的交往中遇到問題,可通過以下方式和我們?nèi)〉寐?lián)系!
          您也可以撥打我們客戶服務熱線:400-0600-280

          *
          *

          MITECH CO. LTD

          TEL :

          86-10-58859527
          008613810243516

          ADD:

          E-506, 1# of ShangDi East Road, Haidian District, Beijing, China

          Email: 

          mvip@mitech-ndt.com

          公眾號
          亚洲国产初高中生女AV,超碰最新公开无码97,亚洲中文字幕无码一,亚洲精品无码专区
            <ul id="xt0w6"></ul>
            <cite id="xt0w6"><listing id="xt0w6"></listing></cite>
              <b id="xt0w6"><meter id="xt0w6"></meter></b>
            1. <thead id="xt0w6"></thead>
                  <form id="xt0w6"><meter id="xt0w6"></meter></form>